HATCHecker

When Hatch Cover Tightness Matters

The HATCHecker is an ultrasound solution designed to test the integrity of vessels for weathertightness. Use HATCHecker to pinpoint the exact location of leaks in hatch covers.

Speak with a Specialist about
Ultrasound Technology

Schedule your consultation

Use HATCHecker to pinpoint the exact location of leaks in hatch covers. The HATCHecker works with SDT’s ergonomic Flexible Sensor and the T-Sonic9 transmitter.

Hatch tightness reporting app

SHERLOGReporter

Hatch cover tightness testing & reporting made easy

SHERLOGReporter
SDT consultation

Consultation With SDT:

Schedule Your Free Consultation To
Talk About Ultrasound Technology

Schedule Your Consultation
General
Function Ultrasound measurement device
Display 160×128 pixel Color OLED
Keyboard 5 function keys
Typical measurement range -6 to 99.9 dBμV (reference 0 dB = 1 μV)
Resolution 0.1 digits
Measurement bandwidth 39.6 to 40.1 kHz
Signal amplification +30 (built-in sensor gain) dB to +102 dB by step of 6 dB
RMS period time 250 milliseconds (main screen) / 3 sec (bar graph)
Sampling frequency 64 kHz
ADC Resolution 12 bit
Minimum sensitivity -31dB (@40 kHz, 0 dB-1 V/µbar)
Environmental
Operating temperature range -10 to +50 °C |14 to 122°F
IP rating IP42
Standards EN 61326-1:2013, EN 55011:2016 + A1:2017, EN 61000-4-2:2009, EN 61000-4-3:2006 + A1:2008 + IS1:2009 +A2:2010
Mechanical
Housing material ABS
Dimensions housing 158 x 59 x 38,5 mm |6.22” x 2.32” x 1.51”
Weight 164g | 5.78oz
Battery/Utility connector USB Mini-B 5-pin
Power
Battery 2 AA batteries
Autonomy 7 hours
Audio
Operable with SDT provided head set only
Maximum audio output (protection) +83dB SPL with SDT headset
Headset 25dB NRR Peltor HQ headset
Other
Warranty Lifetime

Function Ultrasound measurement device Housing material ABS
Display 160×128 pixels Color OLED Dimensions housing 158 x 59 x 38.5 mm | 6.22” x 2.32” x 1.51”
Response time <9 milliseconds Electrical connector 7-pole female LEMO
Measurement channel 1 channel via a 7 pole LEMO connector Weight 164g | 5.78oz
Keyboard 5 function keys Battery 2 AA batteries
Measuring range -6 to 99.9 dBμV (reference 0 dB = 1 μV) Autonomy 7 hours
Resolution 0.1 dBμV Audio Amplification 5 adjustable positions by step of 6 dB
Measurement bandwidth 39.6 to 40.1 kHz Operable with SDT provided head set only
Signal amplification +30 to +102 by step of 6 dB Maximum output +83dB SPL with SDT headset
Operating temperature range -10 to +50 °C |14 to 122°F Headset 25dB NRR Peltor HQ headset
IP rating IP42 Minimum sensitivity -31dB (@40 kHz, 0 dB-1 V/μbar) Egal to a flow rate up to 10-3 std. cm3/sec.