TIGHTChecker
Everything Leaks…
TIGHTChecker is an ultrasound solution designed to verify the tightness of closed volumes.
Use the TIGHTChecker to pinpoint the exact location of leaks in vehicles, buildings, tanks, and ships. Designed for use with SDT’s ergonomic Flexible sensor and compact T-Sonic1 transmitter.
General | |
Function | Ultrasound measurement device |
Display | 160×128 pixel Color OLED |
Keyboard | 5 function keys |
Typical measurement range | -6 to 99.9 dBμV (reference 0 dB = 1 μV) |
Resolution | 0.1 digits |
Measurement bandwidth | 35 to 42 kHz |
Signal amplification | +30 (built-in sensor gain) dB to +102 dB by step of 6 dB |
RMS period time | 250 milliseconds (main screen) / 3 sec (bar graph) |
Sampling frequency | 64 kHz |
ADC Resolution | 12 bit |
Minimum sensitivity | -31dB (@40 kHz, 0 dB-1 V/µbar) |
Environmental | |
Operating temperature range | -10 to +50 °C |14 to 122°F |
IP rating | IP42 |
Standards | EN 61326-1:2013, EN 55011:2016 + A1:2017, EN 61000-4-2:2009, EN 61000-4-3:2006 + A1:2008 + IS1:2009 +A2:2010 |
Mechanical | |
Housing material | ABS |
Dimensions housing | 158 x 59 x 38,5 mm |6.22” x 2.32” x 1.51” |
Flexible rod length (Removable sensor) | 445 mm |17.51” |
Weight | 350g | 12.35 oz |
Battery/Utility connector | USB Mini-B 5-pin |
Power | |
Battery | 2 AA batteries |
Autonomy | 7 hours |
Audio | |
Operable with | SDT provided head set only |
Maximum audio output (protection) | +83dB SPL with SDT headset |
Headset | 25dB NRR Peltor HQ headset |
Other | |
Warranty | Lifetime |
Function | Ultrasound measurement device | Housing material | ABS |
Display | 160×128 pixels Color OLED | Dimensions housing | 158 x 59 x 38.5 mm | 6.22” x 2.32” x 1.51” |
Operable with | SDT provided head set only | Electrical connector | 7-pole female LEMO |
Minimum sensitivity | -31dB (@40 kHz, 0 dB-1 V/µbar) Egal to a flow rate up to 10-3 std. cm3 /sec. |
Weight | 164g | 5.78oz |
Keyboard | 5 function keys | Battery | 2 AA batteries |
Measuring range | -6 to 99.9 dBμV (reference 0 dB = 1 μV) | Autonomy | 4 hours |
Resolution | 0.1 dBμV | Audio Amplification | 5 adjustable positions by step of 6 dB |
Measurement bandwidth | 35 to 42 kHz | Response time | <9 milliseconds |
Signal amplification | +30 to +102 by step of 6 dB | Maximum output | +83dB SPL with SDT headset |
Operating temperature range | -10 to +50 °C |14 to 122°F | Headset | 25dB NRR Peltor HQ headset |
IP rating | IP42 | Operable with | SDT provided head set only |